Outdoor or Indoor use. For particular use with:- a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. b) Cables that exhibit ‘cold flow’ characteristics. c) Enclosures for gas group IIC, under 2 litres in volume and containing an ignition source. d) Enclosures for gas groups IIA or IIB, which are greater than 2 litres in volume and contain an ignition source..
Outdoor or Indoor use. For use with single wire armoured ‘W’, wire braided ‘X’ and steel tape armoured ‘Z’ elastomer and plastic insulated cables. For particular use with:- a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. b) Cables that exhibit ‘cold flow’ characteristics. c) Enclosures for gas group IIC, under 2 litres in volume and containing an ignition source. d) Enclosures for gas groups IIA or IIB, which are greater than 2 litres in volume and contain an ignition source.
Outdoor or Indoor use. For use with single wire armoured ‘W’, wire braided ‘X’ and steel tape armoured ‘Z’ elastomer and plastic insulated cables with a lead inner sheath. For particular use with:- a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. b) Cables that exhibit ‘cold flow’ characteristics. c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area and exceeding 2 litres in volume..
Outdoor or Indoor use. For use with single wire armoured ‘W’, wire braided ‘X’ and steel tape armoured ‘Z’ elastomer and plastic insulated cables. For particular use with:- a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. b) Cables that exhibit ‘cold flow’ characteristics. c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area and exceeding 2 litres in volume..
Outdoor or Indoor use. For use with conduit incorporating individual insulated conductors or for particular use with:- a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. b) Cables that exhibit ‘cold flow’ characteristics. c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area and exceeding 2 litres in volume..
Outdoor or Indoor use. For use with conduit incorporating individual insulated conductors or for particular use with:- a) Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. b) Cables that exhibit ‘cold flow’ characteristics. c) Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area and exceeding 2 litres in volume.
Outdoor or Indoor use. For use with single wire armoured ‘W’, wire braided ‘X’ and steel tape armoured ‘ Z’ elastomer and plastic insulated cables. For particular use with cables that exhibit ‘cold flow’ characteristics.
Outdoor or Indoor use. For use with single wire armoured ‘W’, wire braided ‘X’ and steel tape armoured ‘Z’ elastomer and plastic insulated cables with a lead inner sheath.
Outdoor or Indoor use. For use with single wire armoured ‘W’, wire braided ‘X’ and steel tape armoured ‘Z’ elastomer and plastic insulated cables.
Outdoor or Indoor use.For use with non-armoured elastomer and plastic insulated cables installed in conduit.
Outdoor or Indoor use.For use with non-armoured elastomer and plastic insulated cables.
Outdoor or Indoor use. For use with non-armoured elastomer and plastic insulated cables. May be used on cables incorporating inner and outer cable sheaths.