Hawke
Hazardous Area Cable Glands
501/453/RAC/L
501/414 | 501/421| 501/423 | 501/453/RAC | 501/453/RAC/L | 501/453/Universal | CSB 656 | ICG 623
ICG 653/Universal | ICG 653/Universal/L | PSG 553/RAC | SB 474 | Oversize Cable Glands

Application
Outdoor or Indoor use.
For use with single wire armoured ‘W’, wire braided ‘X’ and steel tape armoured ‘Z’ elastomer and plastic insulated cables with a lead inner sheath.
Features
Provides armour clamping using one clamping arrangement for all armour/braid types.
Provides a seal and an electrical bond on the cables lead inner sheath.
Deluge protection option available.
Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath.
Materials & Finishes
The 501/453/RAC/L Cable Gland is manufactured as standard in Brass, Stainless Steel and Aluminium.
NPT entries are nickel plated as standard.
Full nickel plating by electroplating or electroless plating is also available, as are other materials on request.
Technical Data
Flameproof Exd and Increased Safety Exe.
II 2 GD
Baseefa Certificate No. BAS01ATEX2072X. For sizes O - F.
Baseefa Certificate No. BAS01ATEX2296X. For sizes G - J.
The above certificates are still current, however they are to be superseded by:
Baseefa Certificate No. Baseefa06ATEX0056X. For sizes Os - F.
IECEx Certificate No. IECEx BAS 06.0013X. For sizes Os - F.
Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22.
Suitable for use in Gas Groups IIA, IIB and IIC.
Construction and test standards EN 50014, EN 50018, EN 50019 and EN 50281-1-1. IEC 60079-0, IEC 60079-1 and IEC 60079-7.
IP66, IP67 and IP68 (30 metres for 7 days) ingress protection to IEC 60529, EN 60529 and NEMA 4X.
DTS01 deluge protection certified by ITS.
Operating temperature range -60°C to +80° as standard.
Alternative certification options available:
Option available, Exd IIC, Exe II. Certificate No. 1015065 (LR 78713-7).
Option available, BR-Exd IIC/Exe II.
GOST R-Exd IICU/Exe IIU.
DNV Certificate No.E-8003.

| Cable Gland Selection | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Size Ref. |
Entry Thread Size |
Thread Length ‘H’ |
Cable Acceptance Details | ‘G’ Compressed Length |
Hexagon Dimensions |
||||||||||
| Inner Lead Sheath ‘A’ | Outer Sheath ‘B’ |
‘C’ Armour/Braid |
|||||||||||||
| Metric | NPT * |
Standard Seal+Bond |
Alternative Seal+Bond |
||||||||||||
| Across Flats |
Across Corners |
||||||||||||||
| Standard | Option | Min. | Max. | Min. | Max. | Min. | Max. | Orientation 1 |
Orientation 2 |
||||||
| O | M20 ‡ | ½" | - | 15 | 6.5 | 10.5 | 4.0 | 8.0 | 9.5 | 16.0 | 0.9 / 1.25 | 0 / 0.7 | 65.1 | 24.0 | 27.7 |
| A | M20 | ¾" | ½" | 15 | - | - | 8.5 | 13.0 | 12.5 | 20.5 | 0.9 / 1.25 | 0 / 0.7 | 66.1 | 30.0 | 34.6 |
| B | M25 | 1" | ¾" | 15 | 12.5 | 19.0 | 9.5 | 15.4 | 16.9 | 26.0 | 1.25 / 1.6 | 0 / 0.7 | 71.4 | 36.0 | 41.6 |
| C | M32 | 1¼" | 1" | 15 | 19.0 | 25.0 | 14.5 | 21.2 | 22.0 | 33.0 | 1.6 / 2.0 | 0 / 0.7 | 75.2 | 46.0 | 53.1 |
| C2 | M40 | 1½" | 1¼" | 15 | 25.0 | 31.2 | 22.0 | 28.0 | 28.0 | 41.0 | 1.6 / 2.0 | 0 / 0.7 | 77.1 | 55.0 | 63.5 |
| D | M50 | 2" | 1½" | 15 | 31.5 | 42.3/42.8 † | 27.5 | 34.8 | 36.0 | 52.6 | 1.8 / 2.5 | 0 / 1.0 | 90.3 | 65.0 | 75.1 |
| E | M63 | 2½" | 2" | 15 | 42.0 | 53.3/54.5 † | 39.0 | 46.5 | 46.0 | 65.3 | 1.8 / 2.5 | 0 / 1.0 | 96.7 | 80.0 | 92.4 |
| F | M75 | 3" | 2½" | 15 | 54.5 | 66.0/64.3 † | 48.5 | 58.3 | 57.0 | 78.0 | 1.8 / 2.5 | 0 / 1.0 | 96.0 | 95.0 | 109.6 |
| Larger Cable Glands available in 153/L design as shown below. More details on larger Cable Glands. | |||||||||||||||
| G | M80 | 3½" | - | 20 | 67.0 | 70.0 | - | - | 75.0 | 89.5 | # | # | 95.6 | 106.4 | 123.0 |
| H | M90 | 3½" | - | 20 | 67.0 | 75.0 | - | - | 75.0 | 89.5 | # | # | 95.6 | 115.0 | 132.8 |
| J | M100 | 4" | - | 20 | 75.0 | 89.5 | - | - | 88.0 | 104.5 | # | # | 95.6 | 127.0 | 146.7 |
| † Smaller value is applicable when selecting the option NPT entry thread. ‡ Size O is available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm. O - F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering. All dimensions in millimetres (except*). |
|||||||||||||||
Alternative Reversible Armour Clamping Ring (RAC)
| Selection Table | ||
| Size Ref. | Steel Wire Armour/Braid/Tape | |
| Orientation 1 | Orientation 2 | |
| O/Os | 0.8 / 1.0 | 0.4 / 0.8 |
| A | 0.8 / 1.0 | 0.4 / 0.8 |
| B | 0.9 / 1.25 | 0.4 / 0.8 |
| C | 1.2 / 1.6 | 0.6 / 1.2 |
| C2 | 1.2 / 1.6 | 0.6 / 1.2 |
| D | 1.45 / 1.8 | 1.0 / 1.45 |
| E | 1.45 / 1.8 | 1.0 / 1.45 |
| F | 1.45 / 1.8 | 1.0 / 1.45 |
Cable Gland Ordering Examples
Type/Size/Thread/Standard Inner Seal + Bond
e.g. 501/453/RAC/C/M32/L
501/453/RAC/C/1¼" NPT/L
Cable Gland with Alternative Seal (S)
e.g. 501/453/RAC/C/M32/K
501/453/RAC/C/1¼" NPT/K
Cable Gland With Alternative Clamping Ring
e.g. 501/453/RAC/C/M32/L/AR
501/453/RAC/C/1¼" NPT/L/AR
Hawke Cable Glands | Hawke Enclosures | Hawke EX Connectors | Hawke Adaptors & Reducers
Hawke Transformer Breathers | Hawke Accessories
Contact the Cable Systems Ltd sales office for further details and prices.
Tel: (01925) 852745
Fax: (01925) 820803
Email: sales@cablesystems.co.uk
Recent News
Our sister company JK Electrical has recently launched a new website. JK Electrical are specialist suppliers of Telemecanique products.